Informations
E
Informations
Informationen
Faults - Solutions
Faults Solutions
The unit does not lit up Check - unit/power supply connections
- fuses supply line
Flow rate test Check - calibration factor
- shutters are closed
Repeat the fixed station trial.
Shutters open to maximum then to minimum Check - Tractor drive rate coefficient.
- spreading width
(24.00, beware of the decimal sign)
The unit lits up but the rams do not move Check - Fuses
Area counter reading incorrect Check - connection / machine
- working width
- drive rate
Flow rate Check - programmed flow rate
- fertiliser coefficient
- PDF rate = 540 RPM
- spreading width
- tractor drive rate
- shutter opening/closing performance
- ram travel
- peg marking
The drive rate is incorrect Check - connection on unit
- sensor magnet clearance
- magnet rotation
- sensor wire continuity
(100 ± 10)
- 100-m coefficient
Tonnage counter reading incorrect Check - connection / machine
- working width
- drive rate
- fertiliser coefficient
- shutter opening/closing